VDW.SILVER® RECIPROC® · endo motor · inc 6:1 contra-angle
Reciprocation works because the instrument turns further in the cutting direction than it turns back, and releases before it is loaded to breaking point. Those angles are not built into the file. They are programmed into the motor – which is why VDW tested the two together, and why the RECIPROC setting is a specification rather than a preference.
| 7 PRE-SET SYSTEMS | 15 DR'S CHOICE SLOTS | 6:1 CONTRA-ANGLE IN BOX |
This unit (REF V041163000000): VDW.SILVER® RECIPROC® motor · VDW | Sirona 6:1 contra-angle · foot switch · charger
Made by VDW · a brand of Dentsply Sirona
Every nickel-titanium instrument has an elastic limit – the point at which, if it is bound in the canal, it will fail rather than flex. The whole argument for reciprocation is that the file is released before it gets there. That release is the motor's job, and VDW are explicit that the two were designed as a pair.
“The angles of reciprocation are precise and specific to the design of the RECIPROC® instrument and to the VDW.SILVER® RECIPROC® motor. They are designed to be smaller than the angle settings where the elastic limit of the instrument would be met, thus minimising the risk of instrument fractures.”
VDW, RECIPROC® frequently asked questions (Rev 0, 2010)
The practical consequence is worth stating plainly: a reciprocating file run on angles it was not tested against is a different instrument. If you are buying into RECIPROC, the motor is not the accessory – it is the half of the system that decides how the other half behaves.
It is not a single-system motor. VDW describe it as an endo motor “for reciprocating and continuous rotary nickel-titanium systems”, with pre-set programmes for both and a menu you can work without the manual open beside you.
| Reciprocating | Pre-set programmes for RECIPROC® and WaveOne™ – including RECIPROC ALL on current units |
| Continuous rotary | Pre-set for Mtwo®, FlexMaster®, ProTaper®, K3™ and Gates |
| Dr's Choice | 15 further torque/speed settings you set and store yourself, for rotary systems that are not on the list |
| Power | Battery operated, and it runs while charging – a flat battery does not cost you the appointment |
The programme list above is VDW's own, from their RECIPROC user brochure (Rev 3, 2011). If you need the full library and the exact torque and speed values for a system you already run, ask us and we will send you the operating manual before you order.
› ASR, in rotary mode. Automatic reverse rotation when the set torque limit is reached, with an acoustic warning both when it reverses and at 75% of the set torque – so you hear the canal loading up before the motor has to act on it.
› RECIPROC REVERSE, in RECIPROC mode. A two-stage indicator that tells you when to change what you are doing – the Comfort Function VDW built around the single-file technique.
RECIPROC instruments are single-use, and the unit is the molar, not the case – VDW put it as “single treatment use, maximum one molar”. A two-molar appointment is two files. That is not a hidden cost so much as the trade the system asks for: one instrument doing the work of several, discarded before fatigue becomes a question. Worth doing the arithmetic on your own case mix before you order files.
It has no integrated apex locator. It shapes; it does not measure. If you want length and shaping in one unit that is a different motor and a different budget – talk to us rather than assuming. Everything else in the box is here: contra-angle, foot switch and charger, so it works out of the carton.
| The file it was built for | RECIPROC® blue R25 25 mm · R40 · R50 |
| Hand files | C-PILOT® 010, 25 mm · patency and glide path where the canal asks for one |
| Irrigants | Chlorax 5.25% · Chlorax 2% · Endo-Solution 17% EDTA |
| Delivery | IrriFlex® 30 ga · NaviTip™ 29 ga 25 mm |
| Activation | VDW EDDY® tips · VDW's own, driven by an air scaler rather than this motor |
| Sealer | VDW 2Seal · AH Plus® · or bioceramic, NeoSEALER® EZFlo 25 mm tips |
| Coronal seal | SDR® flow+ Refill Universal · 4 mm bulk increment, one cure |
| Spares for this unit | VDW | Sirona 6:1 contra-angle · foot switch · charger |
Will it run RECIPROC blue?
Yes. The blue instruments are the current RECIPROC® range and run on the RECIPROC setting. The alloy changed; the reciprocation did not.
Can I use it for my rotary system as well?
That is the point of the pre-sets and of Dr's Choice. If your system is not one of the named programmes, you store your own torque and speed in one of the 15 slots.
Does it measure working length?
No – there is no apex locator in this unit. Length stays with your locator or your radiographs.
Is the contra-angle included or extra?
Included – the VDW | Sirona 6:1 comes in the box. It is also sold separately if you want a second, or a replacement.
Can I use it while it is charging?
Yes. VDW state it “is battery operated and can also be used while charging”.
Before you order: settings, torque values and the full pre-set library are in VDW's operating manual, and the file library on current firmware may differ from the list above – ask us for a copy and we will send it before you buy. Instruments are single-use to a maximum of one molar.
VDW.SILVER® RECIPROC® endo motor inc 6:1 contra-angle · reciprocating and continuous rotary · pre-set programmes plus 15 Dr's Choice settings · ASR with acoustic warning · RECIPROC REVERSE · battery, runs while charging · foot switch and charger included · VDW · REF V041163000000
VDW.SILVER® RECIPROC® · endo motor · inc 6:1 contra-angle
Reciprocation works because the instrument turns further in the cutting direction than it turns back, and releases before it is loaded to breaking point. Those angles are not built into the file. They are programmed into the motor – which is why VDW tested the two together, and why the RECIPROC setting is a specification rather than a preference.
| 7 PRE-SET SYSTEMS | 15 DR'S CHOICE SLOTS | 6:1 CONTRA-ANGLE IN BOX |
This unit (REF V041163000000): VDW.SILVER® RECIPROC® motor · VDW | Sirona 6:1 contra-angle · foot switch · charger
Made by VDW · a brand of Dentsply Sirona
Every nickel-titanium instrument has an elastic limit – the point at which, if it is bound in the canal, it will fail rather than flex. The whole argument for reciprocation is that the file is released before it gets there. That release is the motor's job, and VDW are explicit that the two were designed as a pair.
“The angles of reciprocation are precise and specific to the design of the RECIPROC® instrument and to the VDW.SILVER® RECIPROC® motor. They are designed to be smaller than the angle settings where the elastic limit of the instrument would be met, thus minimising the risk of instrument fractures.”
VDW, RECIPROC® frequently asked questions (Rev 0, 2010)
The practical consequence is worth stating plainly: a reciprocating file run on angles it was not tested against is a different instrument. If you are buying into RECIPROC, the motor is not the accessory – it is the half of the system that decides how the other half behaves.
It is not a single-system motor. VDW describe it as an endo motor “for reciprocating and continuous rotary nickel-titanium systems”, with pre-set programmes for both and a menu you can work without the manual open beside you.
| Reciprocating | Pre-set programmes for RECIPROC® and WaveOne™ – including RECIPROC ALL on current units |
| Continuous rotary | Pre-set for Mtwo®, FlexMaster®, ProTaper®, K3™ and Gates |
| Dr's Choice | 15 further torque/speed settings you set and store yourself, for rotary systems that are not on the list |
| Power | Battery operated, and it runs while charging – a flat battery does not cost you the appointment |
The programme list above is VDW's own, from their RECIPROC user brochure (Rev 3, 2011). If you need the full library and the exact torque and speed values for a system you already run, ask us and we will send you the operating manual before you order.
› ASR, in rotary mode. Automatic reverse rotation when the set torque limit is reached, with an acoustic warning both when it reverses and at 75% of the set torque – so you hear the canal loading up before the motor has to act on it.
› RECIPROC REVERSE, in RECIPROC mode. A two-stage indicator that tells you when to change what you are doing – the Comfort Function VDW built around the single-file technique.
RECIPROC instruments are single-use, and the unit is the molar, not the case – VDW put it as “single treatment use, maximum one molar”. A two-molar appointment is two files. That is not a hidden cost so much as the trade the system asks for: one instrument doing the work of several, discarded before fatigue becomes a question. Worth doing the arithmetic on your own case mix before you order files.
It has no integrated apex locator. It shapes; it does not measure. If you want length and shaping in one unit that is a different motor and a different budget – talk to us rather than assuming. Everything else in the box is here: contra-angle, foot switch and charger, so it works out of the carton.
| The file it was built for | RECIPROC® blue R25 25 mm · R40 · R50 |
| Hand files | C-PILOT® 010, 25 mm · patency and glide path where the canal asks for one |
| Irrigants | Chlorax 5.25% · Chlorax 2% · Endo-Solution 17% EDTA |
| Delivery | IrriFlex® 30 ga · NaviTip™ 29 ga 25 mm |
| Activation | VDW EDDY® tips · VDW's own, driven by an air scaler rather than this motor |
| Sealer | VDW 2Seal · AH Plus® · or bioceramic, NeoSEALER® EZFlo 25 mm tips |
| Coronal seal | SDR® flow+ Refill Universal · 4 mm bulk increment, one cure |
| Spares for this unit | VDW | Sirona 6:1 contra-angle · foot switch · charger |
Will it run RECIPROC blue?
Yes. The blue instruments are the current RECIPROC® range and run on the RECIPROC setting. The alloy changed; the reciprocation did not.
Can I use it for my rotary system as well?
That is the point of the pre-sets and of Dr's Choice. If your system is not one of the named programmes, you store your own torque and speed in one of the 15 slots.
Does it measure working length?
No – there is no apex locator in this unit. Length stays with your locator or your radiographs.
Is the contra-angle included or extra?
Included – the VDW | Sirona 6:1 comes in the box. It is also sold separately if you want a second, or a replacement.
Can I use it while it is charging?
Yes. VDW state it “is battery operated and can also be used while charging”.
Before you order: settings, torque values and the full pre-set library are in VDW's operating manual, and the file library on current firmware may differ from the list above – ask us for a copy and we will send it before you buy. Instruments are single-use to a maximum of one molar.
VDW.SILVER® RECIPROC® endo motor inc 6:1 contra-angle · reciprocating and continuous rotary · pre-set programmes plus 15 Dr's Choice settings · ASR with acoustic warning · RECIPROC REVERSE · battery, runs while charging · foot switch and charger included · VDW · REF V041163000000
SpotlightRECIPROC® MinimaOne file · slim shaping for narrow canals
Shaping systems